Your Boiler Model

Arcelik DGK 20 DI — 20 kW wall-mounted gas boiler (natural gas, 2H-G20, 20 mbar). Manufactured by Baymak A.S. for Arcelik. Electrical: 230V / 50Hz, 130W.

Error Codes

When your boiler displays an error code, find it below for a quick diagnosis.

E01

Ignition Failure

The boiler attempted to ignite but failed after multiple tries. Possible causes: gas supply interrupted, ignition electrode dirty or damaged, gas valve fault.

Try first

Check that your gas supply is on (verify other gas appliances work). Check that the gas shutoff valve below the boiler is open (parallel to the pipe = open). Try resetting the boiler by turning it off and on.

Technician

If gas supply is confirmed OK and the error persists after reset, email mainhelp. The ignition electrode or gas valve likely needs servicing.

E02

Safety Thermostat Triggered (Overheating)

The boiler's internal temperature exceeded safe limits and the safety thermostat cut off the flame.

Try first

Wait 10 minutes for the boiler to cool down, then reset. Check that all radiator valves are open (at least 2–3 radiators must be open for proper circulation).

Technician

If error recurs, the circulation pump or heat exchanger may be blocked. Email mainhelp.

E03

Flue Thermostat Fault

Exhaust gas temperature exceeded safe limits, or the flue thermostat sensor is faulty.

Technician

Do not attempt to fix. Email mainhelp — the exhaust system or sensor needs professional inspection.

E04

Repeated Flame Loss

The boiler ignites successfully but keeps losing the flame. Often caused by wind/draft affecting the flue, or intermittent gas supply.

Try first

Reset the boiler. On very windy days, this can be a temporary issue. If it resolves after one reset, no further action needed.

Technician

If error occurs repeatedly even in calm weather, email mainhelp. The flame sensor or flue terminal may need attention.

E05

Heating NTC Sensor Fault

The temperature sensor on the heating circuit is reading out of range (open circuit or short circuit).

Technician

This is a sensor or wiring issue. Email mainhelp.

E06

DHW (Hot Water) NTC Sensor Fault

The temperature sensor on the domestic hot water circuit is faulty. Hot water temperature cannot be properly regulated.

Technician

Sensor replacement required. Email mainhelp.

E10

Low Water Pressure

System pressure has dropped below the minimum threshold (below 0.5 bar). The boiler cannot operate safely without adequate water pressure.

DIY Fix

Look at the pressure gauge on the front of the boiler. Normal operating pressure should be between 1.0 and 1.5 bar. Open the filling valve (small tap underneath the boiler) slowly until the gauge reads ~1.2 bar, then close it. The boiler should reset automatically.

Technician

If you need to top up pressure frequently (more than once a month), there may be a leak in the system. Email mainhelp.

E25

Circulation / Pressure Fault

Air trapped in the system or a pressure irregularity is preventing proper water circulation. This is the most common error reported by residents.

DIY Fix

There is a valve underneath the boiler (usually red). Turn it to the left — this releases excess pressure and resets the boiler. Once water/air stops coming out and pressure normalizes (check the gauge reads ~1.2 bar), close the valve.

Technician

If the E25 error keeps coming back frequently, email mainhelp. There may be a persistent air ingress or pump issue that needs professional attention.

E35

Parasitic Flame Detected

The boiler detects a flame signal when no ignition has been commanded. Usually an ionization electrode or PCB (control board) fault.

Technician

Do not attempt to fix. Turn off the boiler and email mainhelp immediately.

E96

Low Voltage

The electrical supply voltage to the boiler is below acceptable limits.

Try first

Check if there is a general power issue in your apartment. Try unplugging the boiler for 30 seconds and plugging it back in. If there's a voltage stabilizer, check it's working.

Technician

If error persists, the electrical installation may need checking. Email mainhelp.

E98

Gas Valve Fault

Internal gas valve is not operating correctly. The boiler's control board cannot properly command the gas valve.

Technician

Do not attempt to fix. Turn off the boiler and email mainhelp. The gas valve or control board needs professional inspection.

E99

Internal Communication Error

The boiler's internal components cannot communicate with the main control board.

Try first

Turn the boiler off, wait 60 seconds, and turn it back on. This can resolve temporary glitches.

Technician

If error persists after reset, the control board may need replacement. Email mainhelp.

General Tips

How to Reset

Turn the boiler off using the power switch (or unplug it), wait 30–60 seconds, then turn it back on. Most transient errors clear after a reset.

Ideal Pressure

Keep the system pressure between 1.0 and 1.5 bar (check the gauge on the front). Below 0.5 bar or above 2.5 bar will trigger errors.

Winter Prep

Before the heating season, bleed all radiators to remove trapped air. Start from the lowest floor and work up. This prevents E25 errors.

When to Call Help

If you smell gas, hear unusual noises, or see water leaking from the boiler, turn it off immediately and contact security/mainhelp.